Add to Cart
Rack And Floor Mount Online Uninterrupted Power Supply 1000va H1KR for industrial
Technique papameter:
Rack UPS | ||||||||
MODEL | 1KR | 2KR | 3KR | |||||
CAPACITY* | 1000 VA / 800 W | 2000 VA / 1600 W | 3000 VA / 2400 W | |||||
INPUT | ||||||||
Voltage Range | Low Line Transfer | 85VAC/75VAC/65VAC/55VAC±5% or 160VAC/140VAC/120VAC/110VAC±5% (Ambient Temp.<350C) ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) | ||||||
Low Line Comeback | 95VAC/85VAC/75VAC/65VAC or 175VAC/155VAC/135VAC/125VAC ± 5 % (Ambient Temp.<350C) ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) | |||||||
High Line Transfer | 145 VAC ± 5 % or 300 VAC ± 5 % | |||||||
High Line Comeback | 140 VAC ± 5 % or 290 VAC ± 5 % | |||||||
Frequency Range | 40Hz ~ 70 Hz | |||||||
Phase | Single phase with ground | |||||||
Power Factor | ≧ 0.99 @ nominal voltage (input voltage) | |||||||
OUTPUT | ||||||||
Output voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | |||||||
AC Voltage Regulation | ±1% (Batt. Mode) | |||||||
Frequency Range | 47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range) | |||||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | |||||||
Overload | Ambient Temp.<350C 105%~110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass when the utility is normal 110%~130%: UPS shuts down after 1minute at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal | |||||||
Current Crest Ratio | 3:1 | |||||||
Harmonic Distortion | ≦ 3 % THD (linear load); ≦ 6 % THD (non-linear load) | |||||||
Transfer Time | AC Mode to Batt. Mode | Zero | ||||||
Inverter to Bypass | 4 ms (Typical) | |||||||
Waveform (Batt. Mode) | Pure Sinewave | |||||||
EFFICIENCY | ||||||||
AC Mode | 88% | 89% | 90% | |||||
Battery Mode | 83% | 87% | 88% | |||||
BATTERY | ||||||||
Standard Model | Battery Type | 12 V / 9 AH | 12 V / 9 AH | 12 V / 9 AH | ||||
Numbers | 2 | 4 | 6 | |||||
Recharge Time | 4 hours recover to 90% capacity (Typical) | |||||||
Charging Current | 1.0 A (max.) | |||||||
Charging Voltage | 27.4 VDC ± 1% | 54.7 VDC ±1% | 82.1 VDC ±1% | |||||
Long-run Model | Battery Numbers | 2 | 3 | 4 | 6 | 8 | 6 | 8 |
Charging Current | 1.0A/2.0A/4.0A/6.0 A | |||||||
Charging Voltage | 27.4 VDC ± 1% | 41.0VDC ± 1% | 54.7 VDC ±1% | 82.1VDC ±1% | 109.4VDC ±1% | 82.1VDC ±1% | 109.4VDC ±1% | |
PHYSICAL | ||||||||
Standard Model | Dimension, D X W X H | 310 x 438 x 88 (mm) | 410 x 438 x 88 (mm) | 630 x 438 x 88 (mm) | ||||
Net Weight (kgs) | 12 | 19 | 29.3 | |||||
Long-run Model | Dimension, D X W X H | 310 x 438 x 88 (mm) | 410 x 438 x 88 (mm) | 410 x 438 x 88 (mm) | ||||
Net Weight (kgs) | 9 | 12 | 14.2 | |||||
ENVIRONMENT | ||||||||
Operation Humidity | 20-90 % RH @ 0- 40°C (non-condensing) | |||||||
Noise Level | Less than 50dBA @ 1 Meter | |||||||
MANAGEMENT | ||||||||
Smart RS-232 or USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | |||||||
Optional SNMP | Power management from SNMP manager and web browser | |||||||
* Derate capacity to 80% of capacity in Frequency converter mode or when the output voltage is adjusted to 200/208VAC. Product specifications are subject to change without further notice. |